<Data>
Curve setting operation
This section describes the setting procedure of curves which are used with the AFR function and each
mixing function.
Curve type selection
Three types of curves (EXP1, EXP2 and
POINT) can be selected.
Curve type selection
1. Use the EDIT dial to move the cursor
(reverse-video) to the [MODE] item and
push the EDIT button to switch to the
data input mode.
2. Display the curve you want to use by
turning the EDIT dial to the left or right.
*The curve type blinks.
3. When the EDIT button is pushed, the
curve type is changed. (Operate the EDIT
dial or S1 button to stop the change.)
[EXP1]: EXP1 curve
[EXP2]: EXP2 curve
[POINT]: point curve
Setting by curve type
When the curve type is selected as described above, adjustment items corresponding to the curve type
appear on the screen. Adjust each curve as described below.
(reverse-video) to the [RATE A], [RATE B],
[EXP A], or [EXP B] setting item and push
the EDIT button to switch to the data input
mode.
2. Set the rate by turning the EDIT dial to the
left or right.
Initial value: +100.0% (rate)/+0.0% (EXP
rate)
*Initial value differs depending on function.
Adjustment range: -200.0~+200.0%
(rate)/-100.0~+100.0% (EXP rate)
(When the EDIT button is pushed for 1 second, the rate is
reset to the initial value.)
Push the EDIT button to end adjustment
and return to the cursol move mode.
[Offsetting the curve horizontally in the
vertical direction]
1. Use the EDIT dial to move the cursor
(reverse-video) to the [OFFSET] setting item
and push the EDIT button to switch to the
data input mode.
2. Move the curve in the vertical direction by
turning the EDIT dial to the left or right.
Initial value: +0.0%
(When the EDIT button is pushed for 1 second, the rate is
reset to the initial value.)
Push the EDIT button to end adjustment
and return to the cursol move mode.
EXP1/EXP2 curve adjustment
(EXP1 curve)
Using the EXP1 curve is effective in smoothing
starting of the ailerons, elevator, rudder, etc.
(EXP2 curve)
Using the EXP2 curve is effective in engine
rise and other engine control.
The curve left and right rates ([RATE A],
[RATE B]) and EXP curve rate ([EXP A], [EXP
B]) can be adjusted individually. ([EXP] for
EXP2)
The curve can also be offset horizontally
([OFFSET]) in the vertical direction.
[Rate setting]
1. Use the EDIT dial to move the cursor
Vue de la page 122